– 617 –
CHAPTER 5 Operation Procedure for System with PIR
4.4.1 Check Point (1/2)
Confirm the data shown below when service features cannot be assigned or service cannot be operated:
(1) Confirm that line capacity of physical PIR and virtual PIR is set correctly.
(2) Confirm that value of ASYD command to display LP mounting status is assigned as below.
ASYD, SYS1, INDEX198=33
ASYD, SYS1, INDEX199=33
(3) Compare the status of “virtual PIR mounting information” with “physical/virtual PIR line capacity” dis-
played. Data is assigned as below in this system.
ASYD, SYS1, INDEX556=F0
ASYD, SYS1, INDEX557=FF
(4) Confirm that all units are properly mounted by using the AUNT command.