EasyManua.ls Logo

NEC UNIVERGE SV8500 - F TSW Clock Failure

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 222 –
CHAPTER 3 System Messages
1-F: TSW Clock Failure
This message displays when the system detects a clock failure, such as TSW internal clock down or Frame Head
down, in one of the dual systems.
TSW card in which a fault is
detected
Clock status of TSW
0
Clock status of TSW 1
Note: Refer to the meaning of .
Reference: See Chapter 5 Speech Path System Fault - STBY Side Has Become Fault, for the repair procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
MJ 3
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b1 b0
b7 b6 b2 b0
1 2
3
b0: 0/1 = -/TSW 0
b1: 0/1 = -/TSW System 1
1
b2: 0/1 = -/DTG output down
b6: 0/1 = -/External 32 ch Clock (PLO) System 0 down
b7: 0/1 = -/External 32 ch Clock (PLO) System 1 down
2
3
2

Table of Contents

Other manuals for NEC UNIVERGE SV8500

Related product manuals