– 412 –
CHAPTER 3 System Messages
17-H: Day/Night Change Information
This message displays when the NIGHT switch on the ATTCON/DESKCON is operated or when the DAY/
NIGHT change is executed by the external switch operation.
Tenant number
Changing Method
Default Alarm Default Grade Grade Modified Lamp Modified
NON 0
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
Note 1
1
2
3
4
b0-b3: Tenant (1-15)
b4-b7: Tenant (over 15)
1
b0-b7:
1=Night Key on ATTCON/DESKCON
2=External Key
3=ADNM Command (for North America only)
4=Dterm Note 1
5=OAI RCF (for North America only)
Note 1:
In the case of Changing Method 4 (Dterm), “xxxx
xxxx” will indicate the EN of the Dterm performing
Day/Night change.