– 447 –
CHAPTER 3 System Messages
33-G: MUX PKG PCM Parity Error Report
This message displays when PCM parity error occurs on MUX circuit card.
MUX in which a fault occurs
Default Alarm Default Grade Grade Modified Lamp Modified
MN 3
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b4 b3 b2 b1 b0
1
b0-b1: Unit Number
b2: MG Number
b3: MUX System
0/1= System 0/System 1
b4: MUX Status
0/1= ACT/STBY
1