– 251 –
CHAPTER 3 System Messages
4-U: PCI Card Failure
This message displays when a PCI card failure occurs.
Detection of LAN connector fault
LAN3 connector fault status:
F-Bus Link fault
LAN3 connector fault status:
F-Bus Link fault
Default Alarm Default Grade Grade Modified Lamp Modified
MN 3
1: 0X0X XX0X XX0X XX00 2: 000X XX00 000X XX0X 3: XX00 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b3 b2 b1 b0
b7 b3 b2 b1 b0
b7 b2 b1 b0
7
6
5
43
21 8 9
12
1110
13
b0: 0/1 = -/Fault occurrence to LAN3 connector
b1: 0/1 = -/Fault occurrence to LAN2 connector
b2: 0/1 = -/Fault occurrence to LAN1 connector
b3: 0/1 = -/Fault occurrence to LAN4 connector
1
b0: 0/1 = -/Link fault Note 1
b1: 0/1 = -/Late Collision fault
b2: 0/1 = -/Parallel fault
b3: 0/1 = -/Transmission Speed fault
2
b0: 0/1 = -/Carrier loss
b1: 0/1 = -/SQE test error
b2: 0/1 = -/Jabber error
b7: 0/1 = -/Initial fault