– 767 –
CHAPTER 7 Maintenance Commands
CSCL: Continuous Change of Station Class
1. Functional Outline
This command can change the station class information (TEC, RSC, SFC) for a group of stations by specifying
the range of the station number.
2. Parameters
Input Data
TN: Tenant Number
STN(START): First Station Number [0-9, #, * (maximum six digits)]
Note 1
STN(END): Last Station Number [0-9, #, * (maximum six digits)]Note 1
TEC(OLD): Telephone Equipment Class before change [1-31] Note 2, Note 3
TEC(NEW): Telephone Equipment Class after change [1-31] Note 2
RSC(OLD): Route Restriction Class before change [0-15] Note 3
RSC(NEW): Route Restriction Class after change [0-15]
SFC(OLD): Service Feature Class before change [0-15]
Note 3
SFC(NEW): Service Feature Class after change [0-15]
Note 1: In the bottom part of the display, a check box is provided to determine whether to use “*” and “#” as
a part of the station number. If necessary, check the box.
Note 2: Details on Telephone Equipment Class (TEC) are shown below:
1=DP (10pps) 2=PB
3=DP/PB 4=DP (20pps)
5-11=Not used 12=Dterm
13=Data Terminal via Dterm 14=Hot Line
15=CAS line 16=Data Terminal via Data Module
17=Not used 18=Virtual Line Appearance (for Dterm Multi-Line)
19-22=Not used 23=ISDN Terminal
24-26=Not used 27=8 Conference Equipment