ā 207 ā
CHAPTER 3 System Messages
0-D: CPU Clock Down
This message displays when a fault has occurred to the clock oscillator in the CPU.
Self-CPU Restart Information
Male-CPU Restart Information
(FF H: not mounted)
Related Call Information
Reference: See section 4.7.1 on page 640, for the repair procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
MN 3
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
b7 b0
1 2 3
b0: 0/1=-/Monitor Restart
b3: 0/1=-/Initialization
b4: 0/1=Data Copy restart (for Dual-CPU system only)
b5: 0/1=-/MB control
b7: 0/1=ACT/STBY (active system indication after restart)
1
b0: 0/1=-/Monitor Restart
b3: 0/1=-/Initialization
b4: 0/1=-/Data Copy restart (for Dual-CPU system only)
b5: 0/1=-/MB control
b7: 0/1=ACT/STBY (active system indication after restart)
2
b7: 0/1=Released/Not released
3