CHAPTER 5 Operation Procedure for System with PIR
4.8 Control System Fault - STBY Side Is Faulty
•CPU Controlling Block Diagram: See Figure 5-17, Figure 5-18 in this chapter.
Faulty Situation:
Fault has occurred at the STBY side of Dual Configuration system.
•[0-I] STBY CPU Failure.
The ACT side has become faulty, and system changeover has been executed.
•[0-C], [0-H], [0-J] Processor Failure (ACT side)
1-IMG
Replace STBY-side related circuit card
(CPU, GT, TSW, MUX, EMA) with a
spare, and check.
Replace the circuit card (CPU, GT, TSW, MUX,
EMA) individually by referring to the following:
CPU Card Replacement Procedure
EMA Card Replacement Procedure
EXB (EXB-PIR/EXB-TSW) Card
Replacement Procedure
GT Card Replacement Procedure
Replacement Procedure of TSW
(Time Division Switch) Circuit
Card
Replacement Procedure of MUX
(Multiplexer) Circuit Card
Place the circuit card (CPU, GT, TSW, MUX) to
ACT mode by executing CPU or TSW change-
over. (Refer to SYSTEM CONTROL
PROCEDURES)
Check to see if a station-to-station connection can
be set up to identify the circuit card
responsible for the fault.
When a fault is not indicated, set
the faulty systems to STBY side.
Refer to SYSTEM CONTROL
PROCEDURES in Chapter 2.
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
START
END