– 213 –
CHAPTER 3 System Messages
0-H: B1-Level Infinite Loop (Temporary)
This message displays when, in the CPU program processing, the counter value to check the normality of the
processing has become abnormal.
Self-CPU Restart Information
Mate-CPU Restart Information
(FF H: not mounted)
Default Alarm Default Grade Grade Modified Lamp Modified
SUP 1
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b5 b4 b3 b0
b7 b5 b4 b3 b0
b7 b1 b0
1 2
3
b0: 0/1 = -/Monitor Restart
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
b5: 0/1 = -/MB control
b7: 0/1 = ACT/STBY (active system indication after restart)
1
b0: 0/1 = -/Monitor Restart
b3: 0/1 = -/Initialization
b4: 0/1 = -/Data Copy restart (for Dual-CPU system only)
b5: 0/1 = -/MB control
b7: 0/1 = ACT/STBY (active system indication after restart)
2
b0: 0/1 = -/B-Level Infinite Loop
b1: 0/1 = -/Task Timer Timeout
3