– 380 –
CHAPTER 3 System Messages
13-I: CCS Link Failure (Temporary)
This message displays when a failure has occurred numerous times to a common channel signaling link and the
link has been placed into make-busy state. When this fault lasts over three minutes, the system message changes
to [13-H] CCS Link Failure (Permanent)
.
Location of faulty CCH/DCH card
Data Analyzed by NEC Engineers
Default Alarm Default Grade Grade Modified Lamp Modified
NON 1
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
¬
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
3
1
2
b0-b4: Group number
b5, b6:Unit (0-3)
b7: 0/1 = Even-numbered MG/Odd-numbered MG
1
2