– 480 –
CHAPTER 3 System Messages
35-E: SP Failure Recovery
This message displays when any failure has influence on carrying on calls recovered.
Accommodated location of fault-
detected SP or the PH under the
control of SP
Type of failure (FNC)
Failure information (INF)
Default Alarm Default Grade Grade Modified Lamp Modified
NON 1
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
1 2 3
b0-b4: Group (G) No.
b5, b6:Unit (U) No.
b7: Module Group (MG) No.
0/1 = Even-numbered MG/Odd-numbered MG
1
01H: Health check error
2
When = 01 Hex:
01H: MPH failure
02H: PH failure
2
3