EasyManua.ls Logo

NEC UNIVERGE SV8500 - H Digital Line Warning

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 240 –
CHAPTER 3 System Messages
3-H: Digital Line Warning
This message displays when the DTI card detects an abnormal state of a digital line, but this failure has no
influence on the speech path. When the status worsens, the system issues [3-I] Digital Line Failure message.
Location of PM (LENS) with a fault
Kind of fault
Time Slot number of fault (This data
is valid only when the kind of fault
is 08H.)
Default Alarm Default Grade Grade Modified Lamp Modified
SUP 2
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b6 b5 b4 b3 b2 b1 b0
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b3 b2 b1 b0
1 2
3
b0-b4: Group
b5, b6:Unit
b7: 0/1 = Even-numbered MG/Odd-numbered MG
1
01H = Frame alignment loss occurs three times a day
02H = Bit error rate is over 10
-6
03H = Slip occurs twice a day
04H = Multi-frame alignment loss occurs three times a day
08H = Fault-detection on the CCIS Bch
2
b0-b4: Time slot number in which the digital line failure occurred
(1-16, 17-31)
3

Table of Contents