– 818 –
CHAPTER 7 Maintenance Commands
DLSS: Display of Lockout Station - Number
1. Functional Outline
This command is used to print the stations in lockout state by station number.
2. Parameters
Input data
Type: Type of Printout (1-3)
1=Printout of all lockout stations
2=Printout of lockout stations by tenant
3=Printout of lockout stations within a specified range of station number.
TN: Tenant Number
Note 1, Note 2
Start STN: Maximum six digitsNote 2
End STN: Maximum six digitsNote 2
Note 1:
The parameter is valid only when TYPE=2.
Note 2: The parameter is valid only when TYPE=3.
Output data
CNT: Count
TN Tenant Number
STN Physical Station Number
LENS Line Equipment Number