– 749 –
CHAPTER 7 Maintenance Commands
CMWL: Control Message Waiting Lamp
1. Functional Outline
This command indicates ON/OFF status and controls the Message Waiting Lamp ON/OFF (MW Lamp) at the
station. If the station is a Dterm, this command can also control Message Waiting Display on the Dterm.
2. Parameters
Input Data
TYPE: Type of Input (1,2)
1=Designation by Station Number
2=Designation by LEN
TN: Tenant Number
Note 1
STN: A maximum of five digits for a Business system, and six digits for a Hotel system.
Note 1
LENS: Line Equipment Number Note 2
MCI: Message Center MW Status (0,1)
0=OFF
1=ON
ATT: Attendant Console MW Status (0,1)
0=OFF
1=ON
STA: Station MW Status (0,1)
0=OFF
1=ON
VMM: Voice Mail Module MW Status (0,1)
0=OFF
1=ON
Note 1: This parameter appears when “1” is selected in TYPE.
Note 2: This parameter appears when “2” is selected in TYPE.