EasyManua.ls Logo

NEC UNIVERGE SV8500 - Page 271

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 224 –
CHAPTER 3 System Messages
Scan Data 1: Current Status of PLO
card
Scan Data 2: Current Status of PLO
card
b7 b6 b5 b4 b3 b2 b1 b0
b7 b4 b1 b0
b0: Clock status at time of detection
0/1 = STBY/ACT
b1: Circuit Card status at time of detection
0/1 = PLO synchronizing/PLO self running or drift abnormal
b2: 0/1 = -/Input clock down
b3, b4:Route of Input clock
b5: 0/1 = -/PLO input all down
b6: 0/1 = -/PLO output down
b7: 0/1 = -/Drifting
b4 b3 DCS INPUT ROUTE
ROUTE OF INPUT
CLOCK
00 0 0
01 1 1
10 - 2
11 - 3
4
b0: 0/1 = -/Five milliseconds Burst Clock down
b1: 0/1 = -/Frame Synchronization from SYNC card is down
b4: 0/1 = -/Internal OSC clock down
5