EasyManua.ls Logo

NEC UNIVERGE SV8500 - Page 653

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 606 –
CHAPTER 5 Operation Procedure for System with PIR
8
Detection of Release at the
time of Outgoing
Connection
Loop System
Detection of polarity reversal across tip and
ring.
•E&M System
Detection of Release Signal (ground or
–48V) on E lead.
608 milliseconds (standard)
Timing can be assigned using the
ARTD command.
Table 5-5 Timings for Senders
ITEMS FOR STATUS
SUPERVISION
CONDITIONS FOR SUPERVISION TIMING SPECIFICATIONS
1
Sender Acknowledge Wait
Timer
Timing limit for waiting to receive connection
acknowledgement signal from the opposite
office after seizing the opposite office.
4 seconds (standard)
Timing can be assigned using the
ASYD, SYS1, INDEX 130 command.
2
Sender Prepause Timer
Time from sender seizure until sending of the
1st digit where connection acknowledgment is
made by interface with the opposite office.
DP: 3 seconds (standard)
PB: 2.5 seconds (standard)
Timing can be assigned using the
ASYD, SYS1, INDEX 131 command.
3
Sender Inter-digit Timer
Inter-digit timing for the numbers sent out by
the sender.
•For DP
10 pps: 860 milliseconds
(standard)
20 pps: 460 milliseconds
(standard)
Timing can be assigned using the
ASYD, SYS1, INDEX. 132
command.
•For PB
60/120 milliseconds (selected by
ONSG of ARTD command.)
Timing can be changed using the
ASYD, SYS1, INDEX 133
command.
ITEMS FOR STATUS
SUPERVISION
CONDITIONS FOR SUPERVISION TIMING SPECIFICATIONS

Table of Contents