– 25 –
CHAPTER 1 General
Figure 1-7 Unit Number Allocations
FRONT VIEW
IMG0
BASEU
U2 U3
U0
U1
U2
U3
U0
U1
MG01
MG00
IMG2
BASEU
U2 U3
U0
U1
U2
U3
U0
U1
MG05
MG04
IMG3
BASEU
U2 U3
U0
U1
U2
U3
U0
U1
MG07
MG06
IMG1
BASEU
U2 U3
U0
U1
U2
U3
U0
U1
MG03
MG02
PIR3
PIR2
PIR1
PIR0
00 02 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22
MUX (PH-PC36) 0
MUX (PH-PC36) 1
PWR
PWR
Unit Number (U = 0/2) Unit Number (U = 1/3)
Control Control
On each Module Group (MG: 00 - 07), a total of four Units (U0 - U3) can be assigned.
16 16 16 16 16 16
Number
of
Time Slots
Slots No.
PIR
(16)(16)
192 TS192 TS
16 16 16 16 16 16 32 3216 16 16 16 16 16 32 32 32
4-IMG
TOPU
IMG0
BASEU
U2 U3
U0
U1
U2
U3
U0
U1
MG01
MG00
PIR3
PIR2
PIR1
PIR0
1-IMG
TS : Time Slot
(32)