– 687 –
CHAPTER 6 Routine Maintenance Procedure
Attendant Console (ATTCON/DESKCON)
TEST TYPE TEST ITEM CONNECTION DIAGRAM
Call Termination Test Station dials the operator
access code and confirms that
the call termination is
indicated at all the ATTCON/
DESKCON.
Station dials the operator
access code. An attendant
answers and speaks with the
caller. This process is repeated
at all the ATTCON/
DESKCON.
Call Origination Test Attendant originates a call to
the station by pressing LOOP
keys one after another.
ATI
ATTCON/
LC
DESKCON
ATTCON/
LC
~
RG
(RINGING)
ATI
DESKCON