– 740 –
CHAPTER 7 Maintenance Commands
Readout or input data are different depends on Parameter Type. The data in each Parameter Type are shown
below.
<Deleting data, Original data (for copy), Destination Copy, Original data (for move), Destination Move>
Parameter Type=STN is selected, read out or input the following data:
TN: Tenant Number
STN: Physical Station Number (0-9, #, * [Maximum 6 digits])
Phone book Data Num: Number of Local Phone book Data (0-100) is displayed.
Parameter Type=TELN(LDM) is selected, read out or input the following data:
UGN: User Group Number (1-255)
TELN(LDM): Telephone Number (0-9, #, * [Maximum 16 digits])
Phone book Data Num: Number of Local Phone book Data (0-100) is displayed.
Parameter Type=TELN(NDM) is selected, read out or input the following data:
UGN: User Group Number (1-255)
TELN(NDM): Telephone Number (0-9, #, * [Maximum 16 digits])
Phone book Data Num: Number of Local Phone book Data (0-100) is displayed.
Parameter Type=LENS is selected, read out or input the following data:
LENS: Line Equipment Number
Phone book Data Num: Number of Local Phone book Data (0-100) is displayed.
Buttons
Get: Read out the data.
Execute: Start the process.
Exit: Exit this command.