Setting the Output Conditions
232
ZW-7000/5000
User's Manual
Setting the Zero Reset Mode
Setting the Zero Reset Type p.154
As an example, here is an explanation of the procedure for selecting the “REAL” zero reset type setting.
Operating procedure
Steps Key operation Display Description
1 to 5 For moving to “ZERO”, see steps 1 to 5 in p.230.
6 Press the / keys to select “TYPE” and press the
key.
7 Select the zero reset mode.
REAL: Real
HOLD: Hold
Select “REAL” as the zero reset type.
The current setting value is displayed on the sub-display.
Press / key to enter editing mode and the sub-display blinks.
In this example, select “REAL” and press the
key.
8 Press the key for two seconds to enter the RUN mode.