11.4.6 Test Automation
General Scan Configuration..................................................................................673
Scan Table............................................................................................................ 674
Peak Search..........................................................................................................678
Peak Lists..............................................................................................................681
Trace Configuration...............................................................................................682
LISN Settings........................................................................................................ 684
11.4.6.1 General Scan Configuration
[SENSe:]SWEep:COUNt.................................................................................................673
[SENSe:]SWEep:COUNt:CURRent..................................................................................673
TRACe<n>:FEED:CONTrol<t>........................................................................................ 674
TRACe<n>:POINts.........................................................................................................674
[SENSe:]SWEep:COUNt <SweepCount>
This command defines the number of scans performed during a single sweep.
Parameters:
<SweepCount> Range: 0 to 32767
*RST: 0
Example:
SWE:COUN 64
Sets the number of sweeps to 64.
INIT:CONT OFF
Switches to single-sweep mode.
INIT;*WAI
Starts a sweep and waits for its end.
Manual operation: See "Scan Count" on page 189
[SENSe:]SWEep:COUNt:CURRent
This command queries the number of scans that have started in single scan mode with
more than one scan (SENSe:SWEep:COUNt > 1).
Example:
SWE:COUNt 64
sets scan count to 64
INIT:CONT OFF
switches to single scan mode
INIT
starts a scan (without waiting for the scan end!)
SWE:COUN:CURR?
queries the number of started scans
Manual operation: See "Scan Count" on page 189