Remote Control
R&S
®
ESR
705User Manual 1175.7068.02 ─ 12
Parameters:
<Frequency> Range: 0 Hz to fmax
*RST: (STATe to OFF)
Example:
CALC:FLIN2 120MHz
Manual operation: See "Frequency Line 1 / Frequency Line 2 " on page 213
CALCulate<n>:FLINe<k>:STATe <State>
This command turns a frequency line on and off.
Suffix:
<n>
.
Selects the measurement window.
<k> 1 | 2
Selects the frequency line.
Parameters:
<State> ON | OFF
*RST: OFF
Example:
CALC:FLIN2:STAT ON
Manual operation: See "Frequency Line 1 / Frequency Line 2 " on page 213
CALCulate:TFLine:STATe <State>
This command turns a frequency line coupled to the receiver frequency on and off.
Parameters:
<State> ON | OFF
Example:
CALC:TFL:STAT ON
Turns on the frequency line.
Manual operation: See "Tuned Frequency (On Off)" on page 213
11.4.8.3 Using Limit Lines
● Managing Limit Lines............................................................................................ 705
● Configuring Limit Lines..........................................................................................708
● Checking Limits.....................................................................................................717
Managing Limit Lines
CALCulate<n>:LIMit<k>:ACTive?.................................................................................... 706
CALCulate<n>:LIMit<k>:COMMent..................................................................................706
CALCulate<n>:LIMit<k>:COPY........................................................................................706
CALCulate<n>:LIMit<k>:DELete......................................................................................707
CALCulate<n>:LIMit<k>:NAME....................................................................................... 707
CALCulate<n>:LIMit<k>:TRACe...................................................................................... 707
CALCulate<n>:LIMit<k>:UNIT......................................................................................... 708
Remote Commands in Receiver Mode