EasyManua.ls Logo

R&S ESR Series

R&S ESR Series
1126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control
R&S
®
ESR
750User Manual 1175.7068.02 ─ 12
MMEMory:STORe<n>:SPURious <FileName>
This command exports the marker peak list available for spurious emission measure-
ments to a file.
Suffix:
<n>
.
irrelevant
Parameters:
<FileName> String containing the path and name of the target file.
Example:
MMEM:STOR:SPUR 'test'
Saves the current marker peak list in the file test.dat.
Usage: Event
Managing a Sweep List
The following commands configure the sweep list for spurious emission measure-
ments.
[SENSe:]LIST:RANGe<range>:BANDwidth[:RESolution]....................................................750
[SENSe:]LIST:RANGe<range>:BANDwidth:VIDeo.............................................................751
[SENSe:]LIST:RANGe<range>:BREak............................................................................. 751
[SENSe:]LIST:RANGe<range>:COUNt.............................................................................751
[SENSe:]LIST:RANGe<range>:DELete.............................................................................752
[SENSe:]LIST:RANGe<range>:DETector.......................................................................... 752
[SENSe:]LIST:RANGe<range>:FILTer:TYPE..................................................................... 752
[SENSe:]LIST:RANGe<range>[:FREQuency]:STARt..........................................................753
[SENSe:]LIST:RANGe<range>[:FREQuency]:STOP.......................................................... 753
[SENSe:]LIST:RANGe<range>:INPut:ATTenuation............................................................ 754
[SENSe:]LIST:RANGe<range>:INPut:ATTenuation:AUTO...................................................754
[SENSe:]LIST:RANGe<range>:INPut:GAIN:STATe............................................................ 754
[SENSe:]LIST:RANGe<range>:LIMit:STARt...................................................................... 755
[SENSe:]LIST:RANGe<range>:LIMit:STATe...................................................................... 755
[SENSe:]LIST:RANGe<range>:LIMit:STOP.......................................................................756
[SENSe:]LIST:RANGe<range>:POINts.............................................................................756
[SENSe:]LIST:RANGe<range>:RLEVel.............................................................................756
[SENSe:]LIST:RANGe<range>:SWEep:TIME....................................................................757
[SENSe:]LIST:RANGe<range>:SWEep:TIME:AUTO..........................................................757
[SENSe:]LIST:RANGe<range>:TRANsducer.....................................................................757
[SENSe:]LIST:RANGe<range>:BANDwidth[:RESolution] <Value>
This command sets the RBW value for the specified range.
Suffix:
<range>
.
1...20
range
Parameters:
<Value> Refer to the data sheet.
*RST: 30.0 kHz
Remote Commands in Spectrum Analyzer Mode

Table of Contents