Remote Control
R&S
®
ESR
762User Manual 1175.7068.02 ─ 12
Managing a Sweep List
The following commands define a sweep list for SEM measurements.
[SENSe:]ESPectrum:HighSPeed..................................................................................... 762
[SENSe:]ESPectrum:RANGe<range>:BANDwidth[:RESolution].......................................... 763
[SENSe:]ESPectrum:RANGe<range>:BANDwidth:VIDeo................................................... 763
[SENSe:]ESPectrum:RANGe<range>:COUNt................................................................... 764
[SENSe:]ESPectrum:RANGe<range>:DELete...................................................................764
[SENSe:]ESPectrum:RANGe<range>:FILTer:TYPE........................................................... 764
[SENSe:]ESPectrum:RANGe<range>[:FREQuency]:STARt................................................765
[SENSe:]ESPectrum:RANGe<range>[:FREQuency]:STOP................................................ 765
[SENSe:]ESPectrum:RANGe<range>:INPut:ATTenuation...................................................766
[SENSe:]ESPectrum:RANGe<range>:INPut:ATTenuation:AUTO.........................................766
[SENSe:]ESPectrum:RANGe<range>:INPut:GAIN:STATe.................................................. 766
[SENSe:]ESPectrum:RANGe<range>:INSert.................................................................... 767
[SENSe:]ESPectrum:RANGe<range>:LIMit<source>:ABSolute:STARt................................ 767
[SENSe:]ESPectrum:RANGe<range>:LIMit<source>:ABSolute:STOP.................................767
[SENSe:]ESPectrum:RANGe<range>:LIMit<source>:RELative:STARt.................................768
[SENSe:]ESPectrum:RANGe<range>:LIMit<source>:RELative:STOP................................. 768
[SENSe:]ESPectrum:RANGe<range>:LIMit<source>:STATe...............................................769
[SENSe:]ESPectrum:RANGe<range>:RLEVel...................................................................769
[SENSe:]ESPectrum:RANGe<range>:SWEep:TIME..........................................................769
[SENSe:]ESPectrum:RANGe<range>:SWEep:TIME:AUTO................................................770
[SENSe:]ESPectrum:RANGe<range>:TRANsducer...........................................................770
[SENSe:]ESPectrum:HighSPeed <State>
This command activates Fast SEM mode to accelerate spurious emission mask mea-
surements. For details see "Fast Spectrum Emission Mask Measurements"
on page 281.
Note that in Fast SEM mode, the following parameters cannot be changed in all
ranges:
Filter type, see [SENSe:]ESPectrum:RANGe<range>:FILTer:TYPE
on page 764
RBW, see [SENSe:]ESPectrum:RANGe<range>:BANDwidth[:RESolution]
on page 763
VBW, see [SENSe:]ESPectrum:RANGe<range>:BANDwidth:VIDeo
on page 763
Sweep Time Mode, see [SENSe:]ESPectrum:RANGe<range>:SWEep:TIME:
AUTO on page 770
Sweep Time, see [SENSe:]ESPectrum:RANGe<range>:SWEep:TIME
on page 769
Reference level, see [SENSe:]ESPectrum:RANGe<range>:RLEVel
on page 769
RF Att Mode, see [SENSe:]ESPectrum:RANGe<range>:INPut:
ATTenuation:AUTO on page 766
Remote Commands in Spectrum Analyzer Mode

Table of Contents

Related product manuals