Remote Control
R&S
®
ESR
766User Manual 1175.7068.02 ─ 12
[SENSe:]ESPectrum:RANGe<range>:INPut:ATTenuation <Value>
This command sets the attenuation for the specified range.
Note that this parameter can not be set for all ranges if "Fast SEM" mode is activated
(see [SENSe:]ESPectrum:HighSPeed on page 762).
Suffix:
<range>
.
1...20
range
Parameters:
<Value> Refer to the data sheet.
*RST: 0 dB
Example:
ESP:RANG3:INP:ATT 10
Sets the attenuation of range 3 to 10 dB.
Manual operation: See "RF Attenuator" on page 260
[SENSe:]ESPectrum:RANGe<range>:INPut:ATTenuation:AUTO
<State>
This command activates or deactivates the automatic RF attenuation setting for the
specified range.
Note that this parameter can not be set for all ranges if "Fast SEM" mode is activated
(see [SENSe:]ESPectrum:HighSPeed on page 762).
Suffix:
<range>
.
1...20
range
Parameters:
<State> ON | OFF
*RST: ON
Example:
ESP:RANG2:INP:ATT:AUTO OFF
Deactivates the RF attenuation auto mode for range 2.
Manual operation: See "RF Att. Mode" on page 260
[SENSe:]ESPectrum:RANGe<range>:INPut:GAIN:STATe <State>
This command switches the preamplifier on or off for the specified range.
Note that this parameter can not be set for all ranges if "Fast SEM" mode is activated
(see [SENSe:]ESPectrum:HighSPeed on page 762).
Suffix:
<range>
.
1...20
range
Parameters:
<State> ON | OFF
*RST: OFF
Remote Commands in Spectrum Analyzer Mode