No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
144 D
SBU communication error
The SBU connection cannot be detected at power on or recovery from
the energy save mode, or a signal is abnormal.
ï‚§ Defective SBU
ï‚§ Defective harness
ï‚§ Defective detection port on the BICU
1. Replace the harness.
2. Replace the SBU.
3. Replace the BICU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
161
-01
D
BICU error: abnormal LSYNC
The error result of the self-diagnostic by the ASIC on the BICU is
detected at power on or recovery from the energy save mode.
ï‚§ Defective BICU
ï‚§ Defective connection between BICU and SBU
1. Check the connection between BICU and SBU.
2. Replace the BICU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
162
-01
D
BICU error: PCIE communication error
The link up interrupt from LYRA is not detected or the number of
connection lanes is other than 2 at power on or recovery from the
energy save mode.
ï‚§ Defective BICU
ï‚§ Defective connection between BICU and SBU
1. Check the connection between BICU and SBU.
2. Replace the BICU.