SC Tables
D117/D118 6-56 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
-02 A
NVRAM data encryption error 1:
An error occurs while the NVRAM data is encrypted.
ï‚§ Defective NVRAM on the controller board
1. Replace the NVRAM.
-30 A
NVRAM data encryption error 2:
An error occurs before the NVRAM data is encrypted.
ï‚§ Defective controller board
1. Replace the controller board.
-31 A
Other error:
A serious error occurs while the data is encrypted.
ï‚§ Same as SC991
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
859 CTL
HDD Encryption unit error 2
A serious error occurs when the HDD data is encrypted to update an
encryption key with the HDD encryption unit.
-08 B
HDD check error:
The HDD is not correctly installed.
ï‚§ No HDD installed
ï‚§ Unformatted HDD
ï‚§ The encryption key on the controller is different from the one on the
HDD
1. Install the HDD correctly.
2. Initialize the HDD.
-09 B
Power failure during the data encryption:
The data encryption (NVRAM and HDD) has not been completed.
ï‚§ Power failure during the data encryption
1. Initialize the HDD