Chapter 6 — Configuring and Managing Partitions Creating a Storage Partition
November 2016 User GuideSpectra T950 Library
206
2. Selecttheuserswhoareallowedaccesstothispartition.Onlyusers
whowerepreviouslyconfiguredcanbeselected(seeConfiguring
LibraryUsersonpage101).
Notes: Alloftheuserswhoareconfiguredwithoperatorprivileges
arelistedunderAllow only.Selectoneormoreoftheseusers
toenablepartitionbasedsecurityforoperators.
IfyoudidnotconfigureadditionalOperatorlevelusers,you
candosolaterandtheneditthepartitiontogivethemaccess.
Superusersandadministratorsalwayshavefullaccesstoall
partitions.
Configure the Robotic Path Visibility
RoboticpathvisibilitydetermineswhetheroneorbothoftheFibre
Channelportsontheexportingcontrollerprovidetheroboticcontrolpath
totherobotics.
Usethefollowingstepstoconfiguretheroboticpathvisibility.
1. FromthePartitionUsersscreen,clickNext.TheRoboticPathVisibility
screendisplays.
Important
If you are using a tape drive to provide the robotic control path, this is the last
partition configuration screen. Skip to
Confirming and Saving the Partition Settings
on page 211.
Figure 130 Select the port on the exporting controller that is
used to communicate with the robotics.