Chapter 12 — Library Troubleshooting Resetting Components
November 2016 User GuideSpectra T950 Library
369
Reset the LCM or RCM
ToresettheLCMorRCM,insertthetipofatoothpickorothersimilarnon
conductiveobjectintotheholeonthebackoftheLCMorRCMtopressthe
resetbutton.
Caution
Do not use a metallic object to press the reset button. You may inadvertently cause
an electrical short inside the module.
Important
Resetting the RCM resets the motion control for the robotics. Any move requests
fail until the RCM completes its initialization.
Important
Resetting the LCM resets the operator panel and the web server. Any connections
to the library through the BlueScale web interface are lost. Wait five minutes for the
reset to complete and then reconnect. Backup operations are not affected.
Figure 229 The reset button on the Spectra PC.
Figure 230 The reset button on the Spectra LS.
Reset
Reset