Reset the Power Control Module
ThemainframeandeachdriveexpansionframehasaPCM.Toresetthe
over‐currentcircuitthatprotectsthepowersystemintheeventofavoltage
surge,insertthetipofatoothpickorothersimilarnon‐conductiveobject
intotheholeonthebackofthePCMtopresstheresetbutton.
DISCOVERING AND SETTING THE BLUESCALE VISION CAMERA
IP A
DDRESS
IfawhiteBlueScalevisioncameraisconfiguredtouseDHCPaddressing,
youcanusethecamera’ssetupwizardtofindthecameraonthenetwork
anddeterminethecurrentIPaddress.YoucanthenentertheIPaddressin
theBlueScaleSystemSettingsscreen(seeBlueScaleVisionIPAddresson
page114).Youcanalsousethecamera’ssetupwizardtosetafixedIP
address,ifdesired.
ForablackBlueScaleVisioncamera,youcanusethecamera’ssetupwizard
tofindcameraswithbothfixedanddynamicIPaddresses.
Whenyourlibraryenvironmentincludesmultiplecameras,thesetup
wizardsdetectallofthecompatiblecamerasonthenetworkitisaccessing.
WhenyouperformtheinitialIPaddressconfigurationforthecamera
usingthewizard,youmayfindithelpfultoconnectacomputerdirectlyto
theBlueScaleVisioncamera
connectorforonecameraatatimeinsteadof
usingaconnectionoverthenetwork.
Figure 233 Power Control Module reset button.
Power Control
Module (PCM)
Reset
button
If a white camera is configured with an unknown fixed IP address, you must reset it
to use DHCP before you can discover it on the network. Resetting the camera to use
DHCP requires physically accessing the camera inside the library. Contact Spectra
Logic Technical Support for assistance (see
Contacting Spectra Logic on page 7).