TROUBLESHOOTING MLM ISSUES
Thissectionprovidesinformationaboutpotentialissuesthatyoumay
experiencewhileusingMLM.
USB device does
not appear as a
save to” option
MakesurethatyouplugtheUSBdeviceintotheLCMortheoperatorpanel
(T950Bonly),andallowtimeforthedevicetomount,beforeyouselectthe
optionthatsavesdatatotheUSBdevice.
ResettheLCMtomakesurethattheUSBportisnothung(seeResettheLCM
orRCMonpage369).
ThelibraryonlyrecognizesFATformatted,notNTFSformatted,USB
devices.TryusingadifferentUSBdevice.
Issue Resolution
Issue Cause Resolution
An asterisk (*)
appears next to the
barcode on the
MLM Details screen
or an MLM report
Thecartridgewasexportedfromthe
library.
Ifyoudonotintendtoreimport
thecartridge,youcandeleteit
fromtheMLMdatabase(see
DeleteMLMRecordsFromthe
Databaseonpage318).
An “x” appears
next to a barcode
on the Inventory
screen
Thecleaningcartridgeisexpired. Exporttheexpiredcartridgeor
exchangeitforanewone(see
ExportorExchangeExpired
CleaningCartridgesonpage247).
The library does
not proactively
discover new
cartridges when
they are imported
Thediscoveryprocess(MediaAuto
DiscoveryorPreScan)cannotbeginwhile
thehostsareactivelyloadingcartridges
intoorunloadingcartridgesfromthe
drives.Ifyouimportcartridgesduring
thistime,thelibrarypostsafailure
messagestatingthatnodrivesare
availabletoperformthediscovery
process.
Eitherwaituntilthelibraryisidle
beforebeginningtheimportor
manuallystartthediscovery
processforimportedcartridges
whenthelibraryisidle.See
DiscoverCartridgesManuallyon
page296forinstructions.