Chapter 12 — Library Troubleshooting Troubleshooting MLM Issues
November 2016 User Guide—Spectra T950 Library
353
The media health
reported by MLM
for LTO-4 media
changed after it
was loaded into an
LTO - 5 o r LTO- 6
drive
ThealgorithmusedtodetermineMLM
mediahealthinLTO‐5andlater
generationdrivesdiffersfromthe
algorithmusedforLTO‐4drives.For
BlueScalesoftwareversionsearlierthan
BlueScale12.0.7,whenLTO‐4mediais
usedinbothLTO‐4andLTO‐5orLTO‐6
drives,themediahealth
reportedby
MLMisinconsistentbetweenthe
differentdrivegenerations.
BeginningwithBlueScale12.0.7,afteran
LTO‐4cartridgeisloadedintoanLTO‐5
orlatergenerationdrive,thelibrary
adjuststhealgorithmusedtocalculatethe
mediahealthscorewheneverthe
cartridgeissubsequentlyloadedintoan
LTO‐4
drive.Thisadjustmentensuresthat
thereportedmediahealthisconsistent,
regardlessofwhethertheLTO‐4cartridge
isusedinanLTO‐4oranLTO‐5orlater
generationdrive.
AsabestpracticeforyourLTO‐4
media,SpectraLogicrecommends
thatyouconfigureLTO‐4and
LTO‐
5orlatergenerationdrivesin
separatepartitionsandthatyou
donotroutinelyshareLTO‐4
mediabetweenLTO‐4andLTO‐5
orlatergenerationdrives.
LT F S - f o r m a t t e d
LTO - 5 d at a
cartridges are
treated as non-
MLM cartridges
LTO‐5drivesusingfirmwareversion
B6W0orlaterautomaticallymovethe
MLMdataonthecartridgeMAMthefirst
timeacartridgeisloadedandthen
unloadedfromthedrive.Fromthatpoint
forward,theMLMdataismaintainedin
thenewlocation.
IfthecartridgeisformattedtouseLTFS
beforetheMLMdataismoved,the
MLMdataislost.
IfaproperlypreparedandLTFS‐
formattedcartridgeisloadedintoan
LTO‐5drivethatisnotusingfirmware
versionB6W0orlater,thedrivecannot
locateorupdatetheMLMdataonthe
cartridge.
Ifyouplantoreformatyour
LTO‐5datacartridgestouse
LTFS,loadandthenunload
eachcartridgeintoanLTO‐5
drivethatisusingfirmware
versionB6W0orlaterbefore
youreformatthecartridges.
ToensurefullMLMtrackingof
yourLTFS‐formattedLTO‐5
datacartridges,makesureall
LTO‐5drivesinthelibraryare
updatedtofirmwareversion
B6W0orlater.
Issue Cause Resolution