Chapter 9 — Configuring and Using Media Lifecycle Management Using Media Lifecycle Management
November 2016 User GuideSpectra T950 Library
295
Thefollowingtableprovidesinformationaboutdifferentpossible
scenariosforaddingcartridgestotheMLMdatabase.
If you... Do this to add the cartridges to the MLM database...
Recentlypurchasedyour
libraryandareimporting
cartridgesintothelibraryfor
thefirsttime,
1. MakesurethatMLMisenabled(seeEnablingMLMand
ConfiguringGlobalSettingsonpage287).
2. Ifdesired,enablePreScan(seeUsingPreScanonpage298).
3. Importmediaintothepartitionstotriggertheautomaticdiscovery
process.
Important: Discovery cannot begin while the hosts are actively
loading cartridges into and unloading cartridges from drives. If you
import cartridges during this time, the library posts a failure
message stating that no drives are available. Either wait until the
library is idle before importing cartridges or manually start the
discovery process when the library is idle.
Haveanexistinglibrarywith
themostcurrentBlueScale
versioninstalled.Cartridges
arealreadyimportedintothe
library,butyoujustrecently
enabledMLM,
1. IfyouwanttodetectanynonMLMenabledcartridgesbeing
imported,temporarilyenablethealertontheMediaLifecycle
ManagementSettingsscreen(see
EnableAlertsforNonCertified
Mediaonpage289).Thealertisdisabledbydefault.
2. Ifdesired,enablePreScan(seeUsingPreScanonpage298).
3. Discoverthecartridgesinthelibraryusingoneofthefollowing
methods:
Importnewcartridgesintothepartitiontotriggertheautomatic
discoveryprocess.IfyoudonothavePreScanenabled,the
discoveryprocessonlycheckscartridgesthatarenotalreadyin
theMLMdatabase.IfPreScanisenabled,allofthecartridgesin
thepartitionareprocessed,regardlessofwhetherornot
theyare
alreadyintheMLMdatabase.
Important: Discovery cannot begin while the hosts are actively
loading cartridges into and unloading cartridges from drives. If you
import cartridges during this time, the library posts a failure
message stating that no drives are available. Either wait until the
library is idle before importing cartridges or manually start the
discovery process when the library is idle.
Ifyoudonotwanttowaituntilyouimportnewcartridgesto
havethecartridgesalreadyinthelibraryaddedtotheMLM
database,manuallystartthediscoveryprocess(see
Discover
CartridgesManually).
Useyourstoragemanagementsoftwaretoloadeachcartridge
intoanLTO4orlatergenerationdriveandthenunloadit.
LetthelibraryupdatetheMLMdatabaseaspartofnormal
operation.Theinformationforeachcartridgeisaddedtothe
MLMdatabasethefirsttimethecartridgeisloadedintoandthen
unloadedfromanLTO4orlatergenerationdrive.
4. Whentheinitialdiscoveryprocessiscomplete,disablethealert
aboutnonMLMenabledmedia,ifdesired.
5. Toroutinelyverifythereadabilityofthecartridges,configure
PostScanforeachpartitioninthelibrary(see
UsingPostScanon
page299).