Chapter 14 — Maintaining the Library Updating the BlueScale Software and Library Firmware
November 2016 User Guide—Spectra T950 Library
453
Library configuration is corrupted during the update process Usethe
followingstepstorestorethelibrary’sconfigurationifitbecomes
corruptedduringthepackageupdateprocess.
Note: ThelibraryautomaticallysavesaCheckpointConfiguration
Backupfilepriortobeginningapackageupdate.
1. Fromthetoolbarmenu,selectMaintenance > Tools.TheMaintenance
Toolsscreendisplays.
2. SelectUtilities.TheUtilitiesscreendisplays.
3. ClickShow Advanced.TheAdvancedUtilitiesConfirmationscreen
displays.
4. ClickNext.TheUtilitiesscreenrefreshestoshowalistoftheadv anced
utilities.
5. ScrollthroughthelistofadvancedutilitiesandselectRestore
Configuration from Checkpoint.Thescreenrefreshestoshowthedetails
fortheutility.
6. ClickRun Utility torestorethelibrarytotheCheckpointlibrary
configuration.
7. Afterthelibraryconfigurationrestores,performthePackageUpdate
processagain.
The Restore Configuration from Checkpoint utility should only be used
immediately after a package update is performed.
Any library configuration or inventory changes made between the time that the
package update is performed and the utility is run are lost.
Figure 290 The Advanced Utilities screen.