EasyManua.ls Logo

Weiler E2850 - Maintenance Procedures; Air Cleaner Service Indicator - Check; Augers - Inspect; Replace; Auger Segments - Check Torque

Weiler E2850
268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
WEILER E2850 REMIXING TRANSFER VEHICLE
5-8
Maintenance
5
Maintenance Procedures
MAINTENANCE PROCEDURES
Air Cleaner Service Indicator - Check
Replace air filter element when red indicator reaches the
window on indicator (1). Push button (2) to reset
indicator.
Do not remove primary element until indicator shows
replacement is necessary.
Install a new secondary element after the third
replacement of the primary element.
NOTICE: The air restriction indicator will not function
properly if:
Element is damaged or not seated properly in housing.
Air cleaner element body is damaged. If so, unfiltered air may enter engine.
Air transfer duct between air cleaner and engine is damaged or its clamps are loose.
Air duct between air cleaner and restriction indicator is damaged or pinched.
Augers - Inspect / Replace
Corners of new augers are square. As augers wear,
thickness and diameter decrease. When edge (1) wears
to a point, auger should be replaced.
Auger Segments - Check Torque
Dump Hopper Auger Segments
Check auger segments for tightness on shaft. If segments
are loose, torque fasteners (1) to 350 ft-lb (475 Nm).