WEILER E2850 REMIXING TRANSFER VEHICLE
3-49
Operating Instructions
3
Machine Cleanup
Elevator Cleanout
The elevator is equipped with a cleanout door for access to the elevator slats and chains for
inspection, cleaning and material removal.
In the event of a stalled or plugged elevator, run elevator in reverse to remove material from chute
and back into dump hopper if hopper is not fully loaded with material. If dump hopper is full it may
be necessary to open the dump hopper cleanout door to discharge elevator and hopper material onto
the ground.
NOTICE: Do not run dump hopper augers and elevator continuously in reverse if hopper is nearly
full. Auger and hopper damage may occur if material is forced against hopper wall. Momentarily
alternate elevator between reverse and forward to free the stalled elevator.
If stalled elevator cannot be started or the plug will not
move, open elevator cleanout door (1).
NOTICE: Lowering hopper with cleanout door open may
result in damage to door. Close dump hopper cleanout
door before lowering hopper.
If equipped with optional windrow attachment, raise and
latch the windrow/elevator cleanout door frame stop.
1. Fully raise elevator and dump hopper.
2. Unlatch cleanout door legs (2).
3. Lower legs and insert latch pins (3).