WEILER E2850 REMIXING TRANSFER VEHICLE
5-53
Maintenance
5
Maintenance Procedures
Spray Down Filters - Service
1. Lower discharge conveyor.
2. Place a container under filter (1) to catch fluid.
NOTICE: Do not allow dirt to enter system. Thoroughly
clean area around filter before disconnecting.
3. Remove filter (1).
4. Check and clean filter.
5. Install filter.
NOTICE: Machine is equipped with filter (2) only if
60-gallon spray down tank option is installed.
WARNING
Petroleum-based fluids leaked or spilled onto hot surfaces or electrical
components can explode or burn.
Turn ignition switch off when servicing machine. Clean up fluid spills
immediately. No flame. No smoking.