WEILER E2850 REMIXING TRANSFER VEHICLE
5-13
Maintenance
5
Maintenance Procedures
Batteries - Charge
Charging as a 24V System
1. Perform steps 1–5 of "Batteries - Maintenance", page 5-11.
2. Attach 24V charging device to the battery. Observe
polarity and connect cables in the following order:
•Red cable to battery positive (+) terminal (1).
•Black cable to battery negative (-) terminal (2).
•Follow charging device instructions.
3. When charged, disconnect charging device.
Disconnect negative (-) cable, then positive (+) cable.
4. Perform steps 7–12 of
"Batteries - Maintenance",
page
5-11.
Charging as a 12V System
5. Perform steps 1–5 of Battery - Maintenance. Refer to
"Batteries - Maintenance", page 5-11.
6. Remove crossover cable (1) from between batteries,
inspect and replace if damaged.
7. Attach 12V charging device to battery. Observe
polarity and connect cables in the following order:
•Red cable to battery positive (+) terminal.
•Black cable to battery negative (-) terminal.
•Follow charging device instructions.
8. When charged, disconnect charging device. Disconnect negative (-) cable, then positive (+) cable.
9. Repeat procedure for second battery.
10. Perform steps 7–12 of
"Batteries - Maintenance", page 5-11.
Batteries - Replace
NOTICE: Replacement batteries must meet battery
specifications. Refer to
"Batteries", page A-3.
1. Perform steps 1–5 of
"Batteries - Maintenance",
page
5-11.
2. Remove crossover cable (1) from between batteries,
inspect and replace if damaged.
3. Remove battery tie-downs (2) and batteries.
4. Install new batteries and battery tie-downs.
5. Perform steps 7–12 of
"Batteries - Maintenance",
page
5-11.
Discharged
Batteries
24V
Charger
Black
Red
1
2