EasyManua.ls Logo

YASKAWA DX100 - Page 105

YASKAWA DX100
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 System Setup
DX100 8.4 ARM Control
8-40
WEIGHT (unit: kg)
The weight of the installed load is set.
It is not required to set a correct value, however, it is recommended to set
a value slightly larger than the actual load. (Round up the value with each
fraction between 0.5 to 1 kg.)
X (From S-Axis), Y (From S-Axis) (unit: mm)
The center of gravity position of the installed load is set by the distance in
the direction of X and the direction of Y from S axis center here. It can be
set with a rough value.
The direction of X and Y applies to the robot coordinates. The value is set
by a negative number when the position is in “-” direction.
Load on the S-head (Top View)
U-arm payload
Set the weight and the center of gravity position roughly when the
equipment such as the wire supplying motors is installed on U arm.
A standard value is set when shipping from the factory.
Set the weight in “0” if there is no installing equipment on U arm.
WEIGHT (unit: kg)
The weight of the installing load is set here.
Set a little large value though it does not care by a rough value. (Rase to
a unit in each 0.5 to 1kg)
X (From U-Axis), HEIGHT (From U-Axis) (unit: mm)
The center of gravity position of the installing load is set here. It does not
care by a rough value.
X (From U-Axis) is horizontal distance from U axis rotation center to the
center of gravity position of the load. Set negative number when there is
mass side in the back from U-axis rotation center.
HEIGHT (From U-Axis) is height of the vertical direction from U-axis
rotation center to the center of gravity position of the load.
S axis center
(X position, Y position)
+X
+Y
-X
-Y
长沙工控帮教育科技有限公司