13 Description of Units and Circuit Boards
DX100 13.9 Robot Specific Input Terminal Block (MXT)
13-24
Wiring Procedure of the MXT Connector
For your safety, appropriate work must be done by following the
instructions below.
1. Tool: Screwdriver
For the connection, be sure to use a screwdriver of an applicable
size and configuration.
2. Applicable Wires
(1) The length of the exposed conductor (L) should be as follows:
* The length of the exposed conductor set for the terminal block (L)
WAGO series 250 (with 5.0 mm pitch): 9-10 mm
* Applicable max cable outside diameter: 3.1 mm dia.
(2) In case that the conductor is bent or feazed, make it straight as
illustrated in the figure above.
* WAGO standard screwdriver
WAGO 210-119
WAGO 210-119SB (Short,
delivered with the product)