6-44
IM DLM6054-01EN
6.12 Triggering on Combination Triggers (B TRIG)
Procedure
B TRIG Menu
Press B TRIG to display the following menu.
Set the combination type
(OFF, A Delay B, A -> B(N)).
The A trigger (indicates the selected trigger type)
Press to configure the B trigger (Type is fixed at Edge).
Set the delay value.
A Delay B Trigger
A -> B(N) Trigger
Set the number of times
condition B must be met.
Configuring Trigger B (B Trigger)
Press the B Trigger soft key to display the following menu.
The trigger type for trigger B is fixed at Edge. For an explanation of the edge trigger settings, see
section 6.3.
When the Trigger Source Is a Channel from CH1 to CH4
Set the trigger source (CH1, CH4).
Set the trigger slope.
Set the trigger coupling (AC, DC).
Set the HF rejection (OFF, 20 MHz, 15 kHz).
Set the hysteresis ( , ).
Set the trigger level.
Turns the window comparator on and off
Fixed at edge