10-30
IM DLM6054-01EN
Analysis (Measure)
OFF
Analysis is disabled.
Param
You can select parameters.
Mean Mean value
σ
Standard deviation of the histogram
Peak Peak value of the histogram
Integ±
σ
Percentage of measured values that fall within ±
σ
(%)
Integ±3
σ
σ
±
σ
±3
σ
PeakMean
Percentage of measured values that fall within ±3
σ
(%)
Cursor (When the display mode is histogram or trend)
C1 The measured value at cursor C1 is displayed.
C2 The measured value at cursor C2 is displayed.
D
C The difference between the measured values of cursors C1 and C2 is displayed.
Configuring the List Display (Setup)
List Type (Mode)
There are two types of lists that can be displayed.
• Trend
The results of automated measurement from the start of measurement to the present are all
displayed in a list. The measurement items that are displayed are those that have been enabled
in the MEASURE menu.
• Statistics
Statistical processing is performed on the results of automated
measurement from the start of
measurement to the present, and the statistical values that are listed below are displayed for
each measurement item. The measurement items that are displayed are those that have been
enabled in the MEASURE menu.
Current (current value), Max (maximum value), Min (minimum
value), Mean (mean value),
σ
(standard deviation), and Cnt (number of processed values)
Scroll Amount
You can set the number of vertical list entries to scroll through at a time to a value from 1 to 10000.
10.6 Displaying Histograms, Trends, and Lists of Automated Measurements of Waveform Parameters