S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_prog_gpower.fm
Programming a Gated Power Measurement
240 ON TIMEOUT 7,20 CALL Timeout ! Calls "Timeout" routine
250 OUTPUT A;"SETUP:CFER:TIMEOUT:STIME 10 S" !Sets FER measurement timeout to 10 seconds
260 OUTPUT A;"SYST:COMM:GPIB:DEB:STAT ON" !Turns debug state on
270 !
280 !***Set up path loss***
290 OUTPUT A;"SYSTEM:CORRECTION:SFREQUENCY ";Loss_frequency$ !Enters frequencies in
Amplitude Offset table
300 OUTPUT A;"SYSTEM:CORRECTION:SGAIN ";Expected_loss$ !Enters loss values in Amplitude
Offset table
310 !
320 !***Set up call parameters***
330 OUTPUT A;"CALL:OPER:MODE CALL" !Sets Operating Mode to Active Cell
340 OUTPUT A;"CALL:SYSTEM ";Systype$ !Sets System Type
350 OUTPUT A;"CALL:BAND ";Band$ !Sets Cell Band for selected System Type
360 OUTPUT A;"CALL:CHAN ";Channel ! Sets Channel for selected System Type and Cell Band
370 OUTPUT A;"CALL:POWER -50" !Sets and turns on Cell Power for call setup
380 OUTPUT A;"CALL:SID ";Sid! Sets System Identification
390 OUTPUT A;"CALL:NID ";Nid! Sets Network Identification
400 OUTPUT A;"CALL:RCON ";Radio_config$ !Sets Radio Configuration
410 OUTPUT A;"CALL:SOPTION ";Service_opt$ !Sets service option for selected System Type and
Radio Configuration
420 OUTPUT A;"CALL:PROT PREV6" !Sets Protocol Revision for the selected System Type
430 OUTPUT A;"CALL:PAG:DRAT FULL" !Sets Paging channel data rate to full rate
440 OUTPUT A;"CALL:TRAFFIC:DRATE EIGHTH" !Sets traffic/fundamental channel data rate to
eighth
450 OUTPUT A;"CALL:PIL -7" !Sets Pilot to default
460 OUTPUT A;"CALL:SYNC -16" !Sets Sync to default
470 OUTPUT A;"CALL:PAG -12" !Sets Paging to default
480 OUTPUT A;"CALL:FCH -15.6" !Sets Traffic to default
490 !
500 PRINT "Turn on mobile station...press continue when it has found service and registered"
510 PAUSE
520 CLEAR SCREEN
530 OUTPUT A;"CALL:REG:TIMER:STATE OFF" !Turns timer-based registrations off
540 WAIT 2 !Waits 2 seconds for any timer-based registrations to clear out
550 !
560 !***Page the mobile station***
570 DISP "Paging mobile station..."
580 OUTPUT A;"CALL:ORIG" !Pages the mobile station
590 OUTPUT A;"CALL:CONNECTED:STATE?" !Queries for connected/idle state...hangs until state
change detector is disarmed
600 ENTER A;Call_connected
610 IF NOT Call_connected THEN
620 DISP "Call attempt failed"
630 STOP
640 ELSE
650 DISP "Call connected"
660 END IF
670 !
680 !***Set up measurement parameters***
690 OUTPUT A;"SETUP:GPOWER:CONTINUOUS OFF" !Sets trigger arm state to single
700 OUTPUT A;"CALL:POW ";Ior ! Sets Cell Power for gated power measurement
710 OUTPUT A;"CALL:PIL ";Pilot !Sets Pilot channel level

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals