EasyManuals Logo

Agilent Technologies 8960 Series Reference Guide

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #285 background imageLoading...
Page #285 background image
285
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_connected.fm
CALL:CONNected[:STATe]
CALL:CONNected:DROP:TIMer[:STATe]
CALL:CONNected:LIMit[:STATe]
Function Sets/queries the call drop timer. The call drop timer indicates loss of reverse link. This timer also
determines when the demodulation of the reverse link has been unsuccessful for a fixed period.
The call drop timer is actually a counter that counts bad frames. The counter counts for 250
consecutive bad frames (which takes about 5 seconds). The counter is reset whenever a good
frame is received.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST Setting ON
Programming Example
OUTPUT 714;"CALL:CONNECTED:DROP:TIMER:STATE 0"
Function When call limit mode is on, the test set will not respond to the access probe for origination or
page responses from the mobile. For either a base station page or mobile station origination, this
command forces the mobile to repeatedly send access probes.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST Setting ON
Programming Example
OUTPUT 714;"CALL:CONNECTED:LIMIT 0"

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals