Page #300 background imageLoading...
Page #300 background image
300
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_fm.fm
CALL:FM
CALL:FM:INTernal:DEViation
CALL:FM:INTernal:FREQuency
Function Sets/queries the internal FM sources deviation. When querying the internal FM deviation, the
current setting of this parameter will always be returned regardless of the setting for the
internal FM state.
You must make sure that the sum of the three FM sources (internal FM, external FM, and SAT)
do not exceed 20 kHz deviation. The performance of the signal is not specified beyond 20 kHz
deviation.
This command applies in active cell mode while on an AVC, and in AVC test mode.
Setting Range: 0 to 20 kHz
Resolution: 0.1 Hz
Query Range: 0 to 20 kHz
Resolution: 0.1 Hz
*RST Setting 8 kHz
Programming Example
OUTPUT 714;CALL:FM:INTERNAL:DEVIATION 10 KHZ !Sets internal FM deviation to 10 kHz.
Function Sets/queries the frequency of the internal FM source. Applies in active cell mode while on an
AVC, and in AVC test mode.
Setting Range: 20 Hz to 20 kHz
Resolution: 0.1 Hz
Query Range: 20 Hz to 20 kHz
Resolution: 0.1 Hz
*RST Setting 1004 Hz
Programming Example
OUTPUT 714;CALL:FM:INTERNAL:FREQUENCY 60 HZ !Sets the internal FM sources frequency to
!60 Hz.

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals