CALL:MS:REPorted:CAPability:CCHannel:DEDicated
CALL:MS:REPorted:CAPability:CCHannel:DEDicated[:SUPPort]?
CALL:MS:REPorted:CAPability:CCHannel:DEDicated:FRAMe[:SIZE]?
CALL:MS:REPorted:CAPability:CCHannel:DEDicated:FORWard:RCONfig?
CALL:MS:REPorted:CAPability:CCHannel:DEDicated:REVerse:RCONfig?
Function This query only command returns the mobile stations capability to support a dedicated control
channel (DCCH), as reported by the mobile station.
Query Range: YES|NO|UNKN
*RST Setting UNKN
Programming Example
OUTPUT 714;CALL:MS:REPORTED:CAPABILITY:CCHANNEL:DEDICATED:SUPPPORT?
Function This query only command returns the mobile stations capability to support different frame sizes
on the dedicated control channel (DCCH), as reported by the mobile station.
Returned values are 5 millisecond only, 20 milliseconds only, 5 or 20 milliseconds not dynamic, 5
or 20 milliseconds dynamic, or unknown.
Query Range: 5MS|20MS|NDYN|DYN|UNKN
*RST Setting UNKN
Programming Example
OUTPUT 714;CALL:MS:REPORTED:CAPABILITY:CCHANNEL:DEDICATED:FRAME:SIZE?
Function This query only command returns the mobile stations capability to support forward dedicated
control channels, as reported by the mobile station.
This query returns a comma-separated string of any combination of 3, 4, 5, or null.
Query Range: 3|4|5|null
*RST Setting null
Programming Example
OUTPUT 714;CALL:MS:REPORTED:CAPABILITY:CCHANNEL:DEDICATED:FORWARD:RCONFIG?
Function This query only command returns the mobile stations capability to support reverse dedicated
control channels, as reported by the mobile station.
This query returns a comma-separated string of any combination of 3, 4, 5, or null.
Query Range: 3|4|5|null
*RST Setting null
Programming Example
OUTPUT 714;CALL:MS:REPORTED:CAPABILITY:CCHANNEL:DEDICATED:REVERSE:RCONFIG?

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals