EasyManua.ls Logo

Agilent Technologies 8960 Series

Agilent Technologies 8960 Series
786 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
364
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_call_register.fm
CALL:REGister
CALL:REGister:TIMer[:SRPeriod]
CALL:REGister:TIMer:STATe
CALL:REGister:TIMer:RPERiod
Function Sets the time between time based registrations (when timer based registration is on) and turns
the timer based registration state to on.
The value is not the actual time. The registration period is used in the following equation to
determine the time between registrations:
time between registrations= [integer portion of 2
(reg_period/4)
] x 0.08 seconds
Setting Range: 29 to 85
Resolution: integer
Query Range: 29 to 85
*RST Setting 29 (12 seconds)
Programming Example
OUTPUT 714;"CALL:REGISTER:TIMER:SRPERIOD 35"
!Turns the timers state on, and sets the registration period to 35.
Function Sets the state of timer based registrations.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST Setting ON
Programming Example
OUTPUT 714;"CALL:REGISTER:TIMER:STATE OFF"
Function Sets the time between time based registrations (when timer based registration is on). The value
is not the actual time. The registration period is used in the following equation to determine the
time between registrations.
time between registrations = [integer portion of 2
(reg_period/4)
] x 0.08 seconds
Setting Range: 29 to 85
Resolution: integer
Query Range: 29 to 85
*RST Setting 29 (12 seconds)
Programming Example
OUTPUT 714;"CALL:REGISTER:TIMER:RPERIOD 35"