S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_fetch_tferror.fm
FETCh:TFERror
FETCh:TFERror[:ALL]?
FETCh:TFERror:ICOunt?
Function Queries the TDSO frame error rate measurement results.
This measurement returns results in the following order: integrity, frame error ratio (in percent),
received good frames, received blank frames, transmitted good frames, transmitted blank frames,
frame error rate confidence (in percent).
Query Integrity
Range: 0 to 16 see Integrity Indicator
Resolution: 1
TDSO frame error ratio (Ratio)
Range: 0.00 to 100.00%, 9.91 E+37
Received good frames (RX Good)
Range: 0 to 999936, 9.91 E+37
Received blank frames (RX Blank)
Range: 0 to 999936, 9.91 E+37
Transmitted good frames (TX Good)
Range: 0 to 999936, 9.91 E+37
Transmitted blank frames (TX Blank)
Range: 0 to 999936, 9.91 E+37
Frame error rate confidence (in percent)
Range: 0.00 to 100.00%, 9.91 E+37
Resolution: 0.01%
Programming Example
OUTPUT 714;"FETCH:TFERROR?" !Fetches all of the TDSO FER results.
Function Queries the intermediate count of transmitted frames.
To set up the number of transmitted frames, see SETup:TFERror:COUNt .
Query Range: 0 to 999936
Programming Example
OUTPUT 714;"FETCH:TFERROR:ICOUNT?"