747
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_ts_err_msg_pos700.fm
+700 through +799 Error Message Descriptions
+700 through +799 Error Message Descriptions
Description
A device-specific error indicates that the instrument has detected an error that occurred because some
operations did not properly complete, possibly due to an abnormal hardware or firmware condition. For
example, an attempt by the user to set an out of range value will generate a device specific error. Errors are
categorized as follows:
• TA2000: errors common to the test application
• CDMA: errors common to the IS-95 and IS-2000 system type
• Digital2000: errors applicable to only the IS-2000 system type
• Digital95: errors applicable to only the IS-95 system type
When one of these errors is generated, the +700 errors bit in the questionable error status register is set.
Table 20. CDMA Measurement Errors
Error Message Description
+701 Digital average power measurement is not responding
+702 Waveform quality measurement is not responding
+703 Channel power measurement is not responding
+704 Frame error rate measurement is not responding
+705 Access probe power measurement is not responding
Table 21. Digital2000 Measurement Errors
Error Message Description
+701 Handoff waveform quality measurement is not
responding