Appendix D 651
Softkey Functions
Analysis Menu
D. Softkey Functions
(Continued)
Fixture Simulator
Port Matching
Select Circuit
ShuntL -
ShuntC
Adds a shunt L - shunt C type matching circuit to the port selected in the
Select Port menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} PLPC
User Adds a user-defined matching circuit to the port selected in the Select Port
menu. The user-defined matching circuit must be prepared in the 2-port
Touchstone data format and loaded onto the E5070B/E5071B from the
User
File
menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4} USER
Cancel Returns to the softkey display screen one level higher.
C Sets the value of C for the matching circuit selected in the Select Circuit
menu for addition to the port selected in the
Select Port menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4}:PAR:C
G Sets the value of G for the matching circuit selected in the Select Circuit
menu for addition to the port selected in the
Select Port menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4}:PAR:G
L Sets the value of L for the matching circuit selected in the Select Circuit
menu for addition to the port selected in the
Select Port menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4}:PAR:L
R Sets the value of R for the matching circuit selected in the Select Circuit
menu for addition to the port selected in the
Select Port menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4}:PAR:R
User File Opens a dialog box for loading a user-defined 2-port Touchstone data file.
The loaded matching circuit can be added to ports by selecting
User in the
Select Circuit menu.
:CALC{1-16}:FSIM:SEND:PMC:
PORT{1-4}:USER:FIL
Return Returns to the softkey display screen one level higher.
Port ZConversion Displays softkeys for setting up the port impedance conversion function. This function is included in internal
software that converts S parameters determined with a 50 W reference port impedance to S parameters for
arbitrary port impedance.
Port
ZConversion
Enables or disables the port impedance conversion function.
:CALC{1-16}:FSIM:SEND:ZCON:
STAT
Port 1 Z0 Real Sets the reference impedance (real format) of port 1.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT1:Z0
:CALC{1-16}:FSIM:SEND:ZCON:
PORT1:REAL
Port 1 Z0 Imag Sets the reference impedance (complex format) of port 1.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT1:IMAG
Port 2 Z0 Real Sets the reference impedance (real format) of port 2.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT2:Z0
:CALC{1-16}:FSIM:SEND:ZCON:
PORT2:REAL
Port 2 Z0 Imag Sets the reference impedance (complex format) of port 2.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT2:IMAG
Port 3 Z0 Real
*1
Sets the reference impedance (real format) of port 3.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT3:Z0
:CALC{1-16}:FSIM:SEND:ZCON:
PORT3:REAL
Port 3 Z0 Imag
*1
Sets the reference impedance (complex format) of port 3.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT3:IMAG
Port 4 Z0 Real
*2
Sets the reference impedance (real format) of port 4.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT4:Z0
:CALC{1-16}:FSIM:SEND:ZCON:
PORT4:REAL
Port 4 Z0 Imag
*2
Sets the reference impedance (complex format) of port 4.
:CALC{1-16}:FSIM:SEND:ZCON:
PORT4:IMAG
Return Returns to the softkey display screen one level higher.
Key Operation Function SCPI Command